Tone Decoder Control v3.4

MonitorMF

Property MonitorMF
 As Boolean
Read/Write: Read and Write

Description

Set this property true to monitor the R1 MF signals (CCITT R1). Event OnMF() will be fired, if MF tone detected.

Remarks

MF signals: Unacknowledged pulse, multi-frequency signals that are used for forward signaling only. In response to a proceed-to-send signal on the line-signaling system, the MF register transmits the address information en bloc, preceded by the key pulse (KP) signal and terminated by the stop pulse (ST) signal.

R1 MF Tone Specifications

MF Signals (CCITT R1)

Code

Frequency Pairs (Hz)

Name

1

700

900

1

2

700

1100

2

3

900

1100

3

4

700

1300

4

5

900

1300

5

6

1100

1300

6

7

700

1500

7

8

900

1500

8

9

1100

1500

9

0

1300

1500

0

*

1100

1700

KP

#

1500

1700

ST

a

900

1700

ST1

b

1300

1700

ST2

c

700

1700

ST3

The standard length for generating all other R1 MF tones is 68 ms. 

See Also

OnMF